/* USER CODE BEGIN Header */
/**
  ******************************************************************************
  * @file    lora_app.h
  * @author  MCD Application Team
  * @brief   Header of application of the LRWAN Middleware
  ******************************************************************************
  * @attention
  *
  * Copyright (c) 2021 STMicroelectronics.
  * All rights reserved.
  *
  * This software is licensed under terms that can be found in the LICENSE file
  * in the root directory of this software component.
  * If no LICENSE file comes with this software, it is provided AS-IS.
  *
  ******************************************************************************
  */
/* USER CODE END Header */

/* Define to prevent recursive inclusion -------------------------------------*/
#ifndef __LORA_APP_H__
#define __LORA_APP_H__

#ifdef __cplusplus
extern "C" {
#endif

/* Includes ------------------------------------------------------------------*/
/* USER CODE BEGIN Includes */

/* USER CODE END Includes */

/* Exported types ------------------------------------------------------------*/
/* USER CODE BEGIN ET */

/* USER CODE END ET */

/* Exported constants --------------------------------------------------------*/

/* LoraWAN application configuration (Mw is configured by lorawan_conf.h) */
#define ACTIVE_REGION                               LORAMAC_REGION_AS923

/* USER CODE BEGIN EC_CAYENNE_LPP */
/*!
 * CAYENNE_LPP is myDevices Application server.
 */
/*#define CAYENNE_LPP*/
/* USER CODE END EC_CAYENNE_LPP */

/*!
 * Defines the application data transmission duty cycle. 10s, value in [ms].
 */
#define APP_TX_DUTYCYCLE                            10000

/*!
 * LoRaWAN User application port
 * @note do not use 224. It is reserved for certification
 */
//#define LORAWAN_USER_APP_PORT                       2
#define LORAWAN_USER_APP_PORT                       sts_senddataport
#define LORAWAN_USER_APP_HTBT_PORT                  sts_sendhtbtport
#define LORAWAN_USER_APP_CTRL_PORT                  sts_appctrlport
#define LORAWAN_USER_APP_CTRL_REPLY_PORT            sts_appctrl_reply_port


/*!
 * LoRaWAN Switch class application port
 * @note do not use 224. It is reserved for certification
 */
#define LORAWAN_SWITCH_CLASS_PORT                   3

/*!
 * LoRaWAN default class
 */
#define LORAWAN_DEFAULT_CLASS                       CLASS_C
#ifdef	STS_BAT
#define LORAWAN_DEFAULT_CLASS                   	CLASS_A
#endif
/*!
 * LoRaWAN default confirm state
 */
#define LORAWAN_DEFAULT_CONFIRMED_MSG_STATE         LORAMAC_HANDLER_UNCONFIRMED_MSG

/*!
 * LoRaWAN Adaptive Data Rate
 * @note Please note that when ADR is enabled the end-device should be static
 */
#define LORAWAN_ADR_STATE                           LORAMAC_HANDLER_ADR_ON

/*!
 * LoRaWAN Default Data Rate
 * @note Please note that LORAWAN_DEFAULT_DATA_RATE is used only when LORAWAN_ADR_STATE is disabled
 */

#define LORAWAN_DEFAULT_DATA_RATE                   DR_0
#ifdef	STS_BAT
#define LORAWAN_DEFAULT_DATA_RATE                   DR_5
#endif
/*!
 * LoRaWAN Default Tx output power
 * @note LORAWAN_DEFAULT_TX_POWER must be defined in the [XXXX_MIN_TX_POWER - XXXX_MAX_TX_POWER] range,
         else the end-device uses the XXXX_DEFAULT_TX_POWER value
 */
#define LORAWAN_DEFAULT_TX_POWER                    TX_POWER_0

/*!
 * LoRaWAN default activation type
 */
#define LORAWAN_DEFAULT_ACTIVATION_TYPE             ACTIVATION_TYPE_OTAA

/*!
 * LoRaWAN force rejoin even if the NVM context is restored
 * @note useful only when context management is enabled by CONTEXT_MANAGEMENT_ENABLED
 */
#define LORAWAN_FORCE_REJOIN_AT_BOOT                false

/*!
 * User application data buffer size
 */
#define LORAWAN_APP_DATA_BUFFER_MAX_SIZE            242

/*!
 * Default Unicast ping slots periodicity
 *
 * \remark periodicity is equal to 2^LORAWAN_DEFAULT_PING_SLOT_PERIODICITY seconds
 *         example: 2^4 = 16 seconds. The end-device will open an Rx slot every 16 seconds.
 */
#define LORAWAN_DEFAULT_PING_SLOT_PERIODICITY       4

/*!
 * Default response timeout for class b and class c confirmed
 * downlink frames in milli seconds.
 *
 * The value shall not be smaller than RETRANSMIT_TIMEOUT plus
 * the maximum time on air.
 */
#define LORAWAN_DEFAULT_CLASS_B_C_RESP_TIMEOUT      8000

/* USER CODE BEGIN EC */

/* USER CODE END EC */

/* Exported macros -----------------------------------------------------------*/
/* USER CODE BEGIN EM */

/* USER CODE END EM */

/* Exported functions prototypes ---------------------------------------------*/
/**
  * @brief  Init Lora Application
  */
void LoRaWAN_Init(void);

/* USER CODE BEGIN EFP */

/* USER CODE END EFP */

#ifdef __cplusplus
}
#endif

#endif /*__LORA_APP_H__*/