* @brief This function can be used to perform an offset calibration. Offset
* corresponds to the difference in millimeters between real distance and
* measured distance. ST recommend to perform offset at 100m, on a grey17%
* reflective target, but any other distance and reflectance can be used.
* The function returns the offset value found and programs the offset
* compensation into the device.
* @param (Dev_t) dev : instance of selected VL53L4CD sensor.
* @param (int16_t) TargetDistInMm : Real distance between the sensor and the
* target in millimeters. ST recommend 100mm. Min distance is 10mm and max is
* 1000mm.
* @param (int16_t) nb_samples : Number of samples (between 5 and 255). A higher
* number of samples increases the accuracy, but it also takes more time. ST
* recommend to use at least 10 samples.
* @return (VL53L4CD_ERROR) status : 0 if OK, or 255 if something occurred (e.g
* invalid nb of samples).
*/
VL53L4CD_Error VL53L4CD_CalibrateOffset(
Dev_t dev,
int16_t TargetDistInMm,
int16_t *p_measured_offset_mm,
int16_t nb_samples);
/**
* @brief This function can be used to perform a Xtalk calibration. Xtalk
* represents the correction to apply to the sensor when a protective coverglass
* is placed at the top of the sensor. The distance for calibration depends of
* the coverglass, it needs to be characterized. Please refer to the User Manual
* for more information.
* The function returns the Xtalk value found and programs the Xtalk
* compensation into the device.
* @param (Dev_t) dev : instance of selected VL53L4CD sensor.
* @param uint16_t) TargetDistInMm : Real distance between the sensor and the
* target in millimeters. This distance needs to be characterized, as described
* into the User Manual.
* @param (int16_t) nb_samples : Number of samples (between 5 and 255). A higher
* number of samples increases the accuracy, but it also takes more time. ST
* recommend to use at least 10 samples.
* @return (VL53L4CD_ERROR) status : 0 if OK, or 255 if something occurred (e.g
* invalid nb of samples).
*/
VL53L4CD_Error VL53L4CD_CalibrateXtalk(
Dev_t dev,
int16_t TargetDistInMm,
uint16_t *p_measured_xtalk_kcps,
int16_t nb_samples);